Abstract

Leak detection is a common and relevant step of manufacturing processes, which takes place throughout the production line. While several leak test methods have been proposed, pressure decay testing is still widespread due to its lower cost, simplicity and sensitivity in relatively small volumes. However, pressure decay testing is very sensitive to external parameters, mainly temperature. While high-end leak test machines can compensate temperature variations integrating specialized hardware, this paper analyses the viability of applying soft computing models on a regular leak test machine to perform the same compensation. Gaindu, an automation company which sells leak test stations, has customized a leak test station to measure and publish key test data. This data has been stored on a database to be analyzed. Moreover, a model compensating temperature variations has been developed and validated. Results encourage to further vary parameters that may affect the leak test, such as part temperature or humidity, to extend the model and integrate it on commercial leak test machines.

BIB_text

@Article {
title = {Soft Computing Analysis of Pressure Decay Leak Test Detection},
pages = {299-308},
keywds = {
Leak test Process modelling Industry 4.0
}
abstract = {

Leak detection is a common and relevant step of manufacturing processes, which takes place throughout the production line. While several leak test methods have been proposed, pressure decay testing is still widespread due to its lower cost, simplicity and sensitivity in relatively small volumes. However, pressure decay testing is very sensitive to external parameters, mainly temperature. While high-end leak test machines can compensate temperature variations integrating specialized hardware, this paper analyses the viability of applying soft computing models on a regular leak test machine to perform the same compensation. Gaindu, an automation company which sells leak test stations, has customized a leak test station to measure and publish key test data. This data has been stored on a database to be analyzed. Moreover, a model compensating temperature variations has been developed and validated. Results encourage to further vary parameters that may affect the leak test, such as part temperature or humidity, to extend the model and integrate it on commercial leak test machines.


}
isbn = {978-3-030-57802-2},
date = {2021-01-01},
}
Vicomtech

Parque Científico y Tecnológico de Gipuzkoa,
Paseo Mikeletegi 57,
20009 Donostia / San Sebastián (España)

+(34) 943 309 230

Zorrotzaurreko Erribera 2, Deusto,
48014 Bilbao (España)

close overlay

Las cookies de publicidad comportamental son necesarias para cargar el contenido

Aceptar cookies de publicidad comportamental