Robust CT to US 3D-3D Registration by using Principal Component Analysis and Kalman Filtering

Data: 01.07.2016


PDF

Abstract

Algorithms based on the unscented Kalman filter (UKF) have been proposed as an alternative for registration of point clouds obtained from vertebral ultrasound (US) and computed tomography scans, effectively handling the US limited depth and low signal-to-noise ratio. Previously proposed methods are accurate, but their convergence rate is considerably reduced with initial misalignments of the datasets greater than 30 degrees or 30 mm. We propose a novel method which increases robustness by adding a coarse alignment of the datasets’ principal components and batch-based point inclusions for the UKF. Experiments with simulated scans with full coverage of a single vertebra show the method’s capability and accuracy to correct misalignments as large as 180 degrees and 90 mm. Furthermore, the method registers datasets with varying degrees of missing data and datasets with outlier points coming from adjacent vertebrae.

BIB_text

@Article {
title = {Robust CT to US 3D-3D Registration by using Principal Component Analysis and Kalman Filtering},
pages = {52-63},
keywds = {

Registration, Computerized Tomography, Ultrasound, Principal Component Analysis, Kalman filter


}
abstract = {

Algorithms based on the unscented Kalman filter (UKF) have been proposed as an alternative for registration of point clouds obtained from vertebral ultrasound (US) and computed tomography scans, effectively handling the US limited depth and low signal-to-noise ratio. Previously proposed methods are accurate, but their convergence rate is considerably reduced with initial misalignments of the datasets greater than 30 degrees or 30 mm. We propose a novel method which increases robustness by adding a coarse alignment of the datasets’ principal components and batch-based point inclusions for the UKF. Experiments with simulated scans with full coverage of a single vertebra show the method’s capability and accuracy to correct misalignments as large as 180 degrees and 90 mm. Furthermore, the method registers datasets with varying degrees of missing data and datasets with outlier points coming from adjacent vertebrae.


}
isbn = {978-331941826-1},
isi = {1},
doi = {10.1007/978-3-319-41827-8_5},
date = {2016-07-01},
year = {2016},
}
Vicomtech

Gipuzkoako Zientzia eta Teknologia Parkea,
Mikeletegi Pasealekua 57,
20009 Donostia / San Sebastián (Espainia)

+(34) 943 309 230

Zorrotzaurreko Erribera 2, Deusto,
48014 Bilbo (Espainia)

close overlay

Jokaeraren araberako publizitateko cookieak beharrezkoak dira eduki hau kargatzeko

Onartu jokaeraren araberako publizitateko cookieak